GPI Output Settings

Configure the trigger type and other settings for each GPI
output.

GPI output via a network

On GPI outputs via a network, GPI control is performed
using serial tally protocol commands.
GPI outputs can be configured in the same way as parallel
output ports.

• To use GPI via a network, configuration of the SIU

utility connector is required. For details, refer to the
ICP-X7000 Installation Manual.

• This uses a SIU serial tally port, hence the network port

must be configured for a serial tally port.

For details, see “Serial Tally Settings” (page 493).

Configuring GPI Outputs

1

In the Engineering Setup >DCU >GPI Output Assign
menu (7354), select the target GPI output to set.

2

In the <Trigger Type> group, select the trigger
polarity.

(Rising Edge):

Trigger causes the relay to open

or the output to go high level, and holds this state
for the pulse width duration.

(Falling Edge):

Trigger causes the relay to close

or the output to go low level, and holds this state
for the pulse width duration.

(Any Edge):

When a trigger occurs, the relay

opens/closes or the output goes high/low level,
switching state.

Status:

The relay opens/closes or the output goes

high/low level in response to the status.

NOP (No Operation):

The trigger has no effect on the

relay state or the output level.

3

Set the pulse width and timing.

a) 1: Field 1, 2: Field 2, 3: Any

When “Any Edge” is selected as the trigger type, only
the [Timing] parameter is available. When “Status” is
selected as the trigger type, there are no parameter
settings.

4

In the <Source Device> group, select the control panel
to handle the GPI output.

PNL1:

ID1 control panel

PNL2:

ID2 control panel

PNL3:

ID3 control panel

When the action set in step

5

is executed on the control

panel selected in this step, GPI output occurs. It is also
possible to output error information.

For GPI output via a network, SIU1 must be
configured to use [PNL1], and SIU2 must be
configured to use [PNL2]. [PNL3] cannot be used.

5

Select the action to set.

6

Press [Action Set].

Trigger type and actions list

1)

• When the trigger type is other than “Status”

M/E-x Keyx SS ? Recall, P/P Keyx SS ? Recall, No
Action

• When the trigger type is “Status”

M/E-x Keyx SS ? Recall, P/P Keyx SS ? Recall, M/E-x
Keyx On, P/P Keyx On, Error Make, Error Break, Keep
Make, Keep Break, Device Recording, PREFS 1 to
PREFS 16, No Action

1) M/E-x: where x is the M/E number (1 to 5)

Keyx: where x is the key number (1 to 8)

Testing trigger output

In the Engineering Setup >DCU >GPI Output Assign
menu (7354), press [Test Fire].
This outputs a trigger from the selected output port.

This is no output when the trigger type is “Status.”

Notes

No.

Parameter

Adjustment

3

Pulse
Width

Pulse width

4

Timing

Output timing

a)

Note

Note

No.

Parameter

Adjustment

2

Action

Action selection

5

Reg No

Register number

Note