Saving User-Defined Settings

For details about settings that are saved, see “Data Saved
by [Setup Define] and [Init Status Define]” (page 555).

1

Open the Engineering Setup >System >Start Up menu
(7314).

2

Select the target device to set, and perform the
following operation.

• To save Setup settings, press [Setup Define].
• To save Initial Status settings, press [Init Status

Define].

3

Check the message, then press [Yes].

Restoring Initial Status File Settings

You can configure the restoration of switcher settings that
were previously saved when recalling an initial status file
using the File >Setup, Init, VKMem >Initial Status menu
(7112) or File >All, External File >All menu (7161).

• This setting is available only when the target device is

the switcher.

• When [Recall on Load] is enabled and an initial status

file is saved using the File >Setup, Init, VKMem >Initial
Status menu (7112) or File >All, External File >All
menu (7161), the switcher settings at that point in time
are saved.

• When [Recall on Load] is enabled, the switcher settings

are restored when an initial status file is recalled,
regardless of the mode (Resume mode or Custom mode)
selected in the <Start Up Mode> group.
Also, when [Init Status with FM] is enabled, the frame
memory settings

(see page 400)

are also restored.

1

In the Engineering Setup >System >Start Up menu
(7314), select the target device (switcher) to set.

2

In the <Init Status File> group, press [Recall on Load],
turning it on.

3

Press [Execute].

4

Check the message, then press [Yes].

Reset and Initialization

You can reset or initialize memory on each device.

Reset:

Reset to power-on state.

All Clear:

Clear the memory, and reset to factory default

state. The Network Config, System Config, Format, and
Start Up settings are set using data stored in non-volatile
memory, and the system automatically starts up. It is not
necessary to reset the Date/Time settings.

For details, see “Saving and Recalling Setup Data”
(page 400).

Resetting devices and initializing memory

SWR1 and DME1 (and SWR2 and DME3) settings are
linked.

1

In the Engineering Setup >System >Initialize menu
(7315), select the target device to operate.

2

In the <Initialize> group, select one of the following.

Reset:

Reset the device.

All Clear:

Initialize memory.

3

Press [Execute].

4

Check the message, then press [Yes].