In the status area, select the target slot in which the
board is installed.

4

Enable NMOS.

Press [NMOS], turning it on.

When LSM is enabled in the IP Address menu
(7311.2), [NMOS] turns off and NMOS of the target
board becomes disabled.

5

Enable or disable obtaining an address automatically.

To disable, press [RDS Discovery], turning it off.
To enable, press [RDS Discovery], turning it on, and
skip to step

10

.

6

In the <Primary RDS> group, press [IP Address], and
set the IP address of the primary RDS server.

Enter the IP address using the keyboard window, then
press [Enter].

7

In the <Primary RDS> group, press [Port], and set the
port number of the primary RDS server.

Enter the port number using the numeric keypad
window, then press [Enter].

8

In the <Secondary RDS> group, press [IP Address],
and set the IP address of the secondary RDS server.

Enter the IP address using the keyboard window, then
press [Enter].

9

In the <Secondary RDS> group, press [Port], and set
the port number of the secondary RDS server.

Enter the port number using the numeric keypad
window, then press [Enter].

10

Repeat steps

3

to

9

as required.

11

Press [Execute].

12

Check the message, then press [Yes].

Setting the Network Interface
Protocol

On the XVS-8000/7000/6000 with an XKS-Q8111/
XKS-Q8166 installed, you can set the network interface
protocol. NMI (Networked Media Interface) and ST2110
(SMPTE ST 2110 compliant) protocols can be selected.

• On the XVS-9000, the protocol cannot be set. Only the

following protocols are supported on each network
connector board.
- XKS-C9111/XKS-C9121: ST2110
- XKS-C9111N/XKS-C9121N: NMI

• On the XVS-8000/7000/6000, the protocol cannot be set

when the following network connector boards are
installed. Only the following protocols are supported on
each network connector board.
- XKS-T8110/XKS-T8165: NMI
- XKS-C8111/XKS-C8166: ST2110

• The protocol setting is common to all slots in which an

XKS-Q8111/XKS-Q8166 is installed. If different
protocols are displayed among the slots, reconfigure the
protocol setting.
Network connector boards that use different protocols
cannot be installed in a switcher at the same time.

1

In the Engineering Setup >System >Network Config
menu (7311), press [Net I/F Protocol].

The Net I/F Protocol menu (7311.3) appears.

2

In the <Device> group, select the target switcher to set.

3

In the status area, select a slot.

4

In the <Net I/F Protocol> group, select one of the
following.

NMI:

Set to NMI.

ST2110:

Set to SMPTE ST 2110 compliant.

The selected protocol is displayed for all slots in which
an XKS-Q8111/XKS-Q8166 is installed.

5

Press [Execute].

6

Check the message, then press [Yes].

Note

Notes