2

Select the target table to set.

3

Select the target button number to set.

4

Select the pair signal to assign.

5

In the <Button Assign> group, select one of the
following.

Set:

Delete the signal currently assigned to the

selected button number and make a new
assignment.

Insert:

Move the signal currently assigned to the

selected button number to the next number, and
make a new assignment.

To inhibit operation of buttons

Select the target button number to set, and press [Inhibit].

To delete a signal assigned to a button

Select the button number, and press [Delete] in the
<Button Assign> group.
The signals assigned to numbers following the selected
button number move up in sequence.

To return the table settings to the defaults

Press [Default Recall], check the message, then press
[Yes].

Setting the [SHIFT] button operation mode

This sets the operation of the [SHIFT] button assigned to
the right edge of the cross-point button row. The setting
can be configured for each cross-point assign table (main,
1 to 14).

On the cross-point control block, the [SHIFT] button
operation mode is set by the settings of the cross-point
assign table of the switcher bank (M/E or P/P), regardless
of the buses assigned to the cross-point button rows.

1

In the Engineering Setup >Panel >Xpt Assign >Main,
V/K Pair Assign menu (7322.5) or the Engineering
Setup >Panel >Xpt Assign >Table Button Assign
menu (7322.1), press [Shift Mode].

The Shift Mode menu (7322.13) appears.

2

Select the target table to set.

3

In the <Xpt Shift Mode> group, select the operation
mode of the [SHIFT] button.

Hold:

Functions as a shift button, and the shifted state

of the cross-point buttons is enabled while the
button is held down.

Lock:

Functions as a shift button, and pressing the

button toggles between the shifted and unshifted
cross-points.

Off:

Functions as a cross-point button, namely, button

number 20 on a 20-button system, button number
28 on a 28-button system, and button number 36
on a 36-button system.

Setting the [SHIFT ALL] button operation
mode

This sets the operation mode of the [SHIFT ALL] button
assigned to the cross-point pad. This settings is common to
all cross-point assign tables.

1

In the Engineering Setup >Panel >Xpt Assign >Main,
V/K Pair Assign menu (7322.5) or the Engineering
Setup >Panel >Xpt Assign >Table Button Assign
menu (7322.1), press [Shift Mode].

The Shift Mode menu (7322.13) appears.

2

Press [Shift All Hold] and set the [SHIFT ALL] button
operation mode.

To enable the shifted-state cross points for all buses
while the button is pressed, press [Shift All Hold],
turning it on (hold mode).
To switch between shifted-state and unshifted-state
cross points for all buses each time the button is
pressed, press [Shift All Hold], turning it off (lock
mode).

Setting the source signal name

1

In the Engineering Setup >Panel >Xpt Assign menu
(7322) or the Engineering Setup >Panel >Xpt Assign
>Table Button Assign menu (7322.1), press [Src
Name/Src Color].

The Src Name/Src Color menu (7322.6) appears.

2

Select the target signal to set.

3

Press [Source Name].

4

Enter a name of up to 16 characters in the keyboard
window, and press [Enter].

No.

Parameter

Adjustment

1

Table No

Selection of the table to set

Note

No.

Parameter

Adjustment

1

Source No

Source signal selection

2

Num

Number to select