5

AG-1021

Message

Unable to do Preferred-Failover of F_Port <port number>. Failover across different
fabric is not supported.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that failover across N_Ports connected to different fabrics is not supported.

Recommended

Action

Change the preferred N_Port settings of the specified F_Port using the ag --prefset command.

Choose the preferred N_Port so that it is in the same fabric as the primary N_Port of this F_Port. Execute
the ag --show command to check the fabric connectivity of the N_Ports.

AG-1022

Message

F_Port <f_port> is failed over to its preferred N_Port <n_port>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the specified F_Port is failing over to its preferred N_Port.

Recommended

Action

Execute the ag --mapshow command to display the updated F_Port-to-N_Port mapping.

AG-1023

Message

F_Port <f_port> mapped to offline N_Port <n_port> is failed over to its preferred
N_Port <preferred port>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified N_Port has failed to come online. The F_Port mapped to this N_Port had its
preferred set and is online.

Recommended

Action

Execute the ag --mapshow command to display updated F_Port-to-N_Port mapping.