Fabric OS Message Reference

845

53-1002749-01

SWCH-1007

5

SWCH-1007

Message

Switch port <port number> disabled due to \"<disable reason>\".

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the switch port is disabled due to the reason displayed in the message.

Recommended

Action

Based on the disable reason displayed, take appropriate action to restore the port.

If the disable reason is "Insufficient frame buffers", reduce the distance or speed settings for the port to
reduce the buffer requirement of the link. Alternatively, one or more ports in the port group must be
disabled to make more buffers available for the link.

Refer to the Fabric OS Administrator's Guide for more information.

SWCH-1008

Message

<area string> are port swapped on ports that do not support port swap. Slot <slot
number> will be faulted.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the blade enabled with the port configuration that does not support port swap.

Recommended

Action

Replace the blade with ports that support port swap. Then swap ports back to the port's default area.

Refer to the Fabric OS Administrator's Guide for more information on port swapping.

SWCH-1009

Message

Shared area having Trunk Area (TA) enabled on slot <slot number>. Shared areas
that have TA enabled will be persistently disabled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the blade is enabled with a port configuration that had Trunk Area previously enabled on
the shared area port.

Recommended

Action

Disable Trunk Area on ports that had Trunk Area enabled previously. Refer to the Fabric OS
Administrator's Guide
for more information.