620

Fabric OS Message Reference

53-1002749-01

MS-1009

5

MS-1009

Message

RLIR event. Slot/Port <slot number>/<port number> (0x<PID (hex)>). Device Port Tag
is 0x<port tag>. <message text>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a registered link incident record (RLIR) has been generated for one of the actions indicated by
the message value.

The message value can be one of the following:

•

Exceeded bit error rate threshold

•

Loss of signal or synchronization

•

Not operational seq recognized

•

Primitive sequence timeout

•

Unrecognized link incident

Recommended

Action

Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or small
form-factor pluggable (SFP) transceivers. If the message persists, replace hardware.

MS-1021

Message

MS WARMBOOT failure(FSS_MS_WARMINIT failed. Reason=<failure reason>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT
phase of a reboot.

Recommended

Action

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

MS-1022

Message

Management Server Platform Service <Activated or Deactivated>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the Management Server (MS) platform service is being activated or deactivated.

Recommended

Action

No action is required.