Fabric OS Message Reference

53-1002749-01

MS-1009

5

MS-1009

Message

RLIR event. Slot/Port <slot number>/<port number> (0x<PID (hex)>). Device Port Tag
is 0x<port tag>. <message text>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a registered link incident record (RLIR) has been generated for one of the actions indicated by
the message value.

The message value can be one of the following:

Exceeded bit error rate threshold

Loss of signal or synchronization

Not operational seq recognized

Primitive sequence timeout

Unrecognized link incident

Recommended

Action

Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or small
form-factor pluggable (SFP) transceivers. If the message persists, replace hardware.

MS-1021

Message

MS WARMBOOT failure(FSS_MS_WARMINIT failed. Reason=<failure reason>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT
phase of a reboot.

Recommended

Action

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

MS-1022

Message

Management Server Platform Service <Activated or Deactivated>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the Management Server (MS) platform service is being activated or deactivated.

Recommended

Action

No action is required.