Fw-1051, Fw-1052, Fw-1053 – Dell POWEREDGE M1000E User Manual

Page 470

Advertising
background image

448

Fabric OS Message Reference

53-1002749-01

FW-1051

5

FW-1051

Message

<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. High voltages indicate possible hardware failures.

Recommended

Action

Frequent voltage fluctuations indicate that the SFP is deteriorating. Replace the SFP.

FW-1052

Message

<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1053

Message

<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) Power on Hours has fallen below the
low boundary.

Recommended

Action

Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.