Ficn-1118, Ficn-1119, Ficn-1120 – Dell POWEREDGE M1000E User Manual

Page 435

Advertising
background image

Fabric OS Message Reference

413

53-1002749-01

FICN-1118

5

FICN-1118

Message

HostPrintIng::FICON Selective Reset:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> state=0x<the current emulation
state for this device> LastCmds=0x<the last 4 commands received from the channel
for this device> LastStatus=0x<the last 4 status values presented to the channel
for this device>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the channel recognized a timeout condition and issued a Selective Reset.

Recommended

Action

If this was an unexpected event, contact your vendor's customer support for assistance.

FICN-1119

Message

HostPrintIng:FICON Selective Reset:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> Elapsed Time=<the number of
seconds since the last IO started for this device>.<the number of milliseconds
since the last IO started for this device> seconds.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the channel recognized a timeout condition and issued a Selective Reset.

Recommended

Action

If this was an unexpected event, contact your vendor's customer support for assistance.

FICN-1120

Message

HostPrintIng:FICON Purge received:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a Purge Path was received from the locally connected FICON channel. This is performed
during FICON path recovery.

Recommended

Action

If this was an unexpected event, contact your vendor's customer support for assistance.

Advertising