Fabric OS Message Reference

185

53-1002749-01

BM-1010

5

BM-1010

Message

Resetting port configuration and linkcost for all ports for blade in slot <Slot
number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the specified blade was detected for the first time after an FC10-6 was previously configured in
the same slot. The new blade requires resetting the port configuration and linkcost.

Recommended

Action

No action is required. The blade ports are cleared automatically.

BM-1053

Message

Failed to establish connection between CP and Application Processor. Faulting
switch.

Message Type

LOG | FFDC

Severity

WARNING

Probable Cause

Indicates that the control processor (CP) could not establish a connection with the application processor
(AP) to communicate.

Recommended

Action

Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade.

BM-1054

Message

AP firmware <Blade firmware> is not consistent with system firmware <System
firmware>. Auto-leveling AP firmware to match system firmware.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the policy of the specified blade is set to auto-level the blade firmware to the system
firmware. This may be due to one of the following reasons:

Blade firmware was detected to be different from the control processor (CP) firmware due to a
firmware upgrade.

The blade was recently inserted and had a different version of the firmware loaded.

Recommended

Action

No action is required. The blade will automatically download the updated firmware.