Fabr-1041, Fabr-1043, Fabr-1044 – Dell POWEREDGE M1000E User Manual

Page 338

Advertising
background image

316

Fabric OS Message Reference

53-1002749-01

FABR-1041

5

FABR-1041

Message

Port <Port that is being disabled> is disabled due to trunk protocol error.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a link reset was received before the completion of the trunking protocol on the port.

Recommended

Action

Enable the port by running the portEnable command.

The port may recover by re-initialization of the link.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.

FABR-1043

Message

Detected Fabric ID conflict with remote (not neighbor) switch <Switchname> (domain
<Domain ID>), FID <Fabric ID>. No local E_Ports disabled.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the remote switch has a Fabric ID (FID) conflict with the local switch. But no ports are
disabled because the remote switch is not an adjacent to the local switch.

Recommended

Action

Make sure that all the switches in the fabric have the same FID or upgrade the switch firmware to a
VF-capable firmware.

FABR-1044

Message

Detected Fabric ID conflict with neighbor switch <Switchname> (domain <Domain
ID>), FID <Fabric ID>. E_Ports (<Number of E_Ports disabled>) connected to the
switch are disabled.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the neighbor switch has a Fabric ID (FID) conflict with the local switch. All E_Ports directly
connected to the conflicting switch are disabled.

Recommended

Action

Make sure that all the switches in the fabric have the same FID or upgrade the switch firmware to a
VF-capable firmware.