Sec-1049, Sec-1050, Sec-1051 – Dell POWEREDGE M1000E User Manual

Page 721

Advertising
background image

Fabric OS Message Reference

699

53-1002749-01

SEC-1049

5

SEC-1049

Message

Invalid switch name <switch name>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

SEC-1050

Message

There are more than one switches with the same name <switch name> in the fabric.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

SEC-1051

Message

Missing brace for port list <port list>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

Advertising