Ficn-1069, Ficn-1070, Ficn-1071 – Dell POWEREDGE M1000E User Manual

Page 418

Advertising
background image

396

Fabric OS Message Reference

53-1002749-01

FICN-1069

5

FICN-1069

Message

Emulation Configuration Error on TunnelId <Tunnel ID>:.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an error has been noted in the FICON configuration. Refer to the string for the nature of the
configuration issue.

Recommended

Action

If resolution of the configuration issue cannot be completed, contact your vendor's customer support for
assistance.

FICN-1070

Message

DevTapeIngr:Exceptional Status rcvd on Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> state=0x<current emulation
state> status=0x<the exceptional status value>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the normal end of tape status (0x0D or 0x05) is received from the device or error status
(including Unit Check 0x02) is received from an active emulation device.

Recommended

Action

The end of tape is a normal event during pipelining and not the unit check. If there are associated I/O
error messages with this event, contact your vendor's customer support for assistance.

FICN-1071

Message

HostTapeIngr:Tape Loaded on Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the tape I/Os are processed from a locally connected Logical Partition (LPAR), which indicates
that a tape is loaded on a device.

Recommended

Action

No action is required.

Advertising