C2-1013, C2-1014, C2-1015 – Dell POWEREDGE M1000E User Manual

Page 212

Advertising
background image

190

Fabric OS Message Reference

53-1002749-01

C2-1013

5

C2-1013

Message

S<slot number>,P<port number>(<blade port number>): Duplicate rte_tbl_select
detected.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the selected table is corrupted.

Recommended

Action

This message must have a matching message for the other duplicate table. Reset both the specified
ports. If it is a trunk, reset the entire trunk.

C2-1014

Message

Link Reset on Port S<slot number>,P<port number>(<blade port number>) vc_no=<vc
number> crd(s)lost=<Credit(s) lost> <Source of link reset > trigger.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or more credits are lost and the link is reset.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

C2-1015

Message

Port re-initialized due to Link Reset failure on internal Port S<slot
number>,P<port number>(<blade port number>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port is re-initialized due to link reset failure.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

Advertising