Nbfs-1003, Nbfs-1004 – Dell POWEREDGE M1000E User Manual

Page 650

Advertising
background image

628

Fabric OS Message Reference

53-1002749-01

NBFS-1003

5

NBFS-1003

Message

DB_XMIT_SET flag not set in state <current state name>, input <state name>, port
<portnumber>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the database transmit set flag was not set for the specified input state on the specified port.
Neighbor finite state machine (NBFSM) states are as follows:

0 - Down

1 - Init

2 - Database Exchange

3 - Database Acknowledge Wait

4 - Database Wait

5 - Full

Recommended

Action

No action is required. The Fabric OS automatically recovers from this problem.

NBFS-1004

Message

Wrong input: <state name> to neighbor FSM, state <current state name>, port
<portnumber>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the wrong input was sent to the neighbor finite state machine (NBFSM). NBFSM states are as
follows:

0 - Down

1 - Init

2 - Database Exchange

3 - Database Acknowledge Wait

4 - Database Wait

5 - Full

If this error occurs repeatedly, then there is a problem in the protocol implementation between two
switches.

Recommended

Action

Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is
Full, then this message can safely be ignored. Otherwise, run the portDisable and portEnable
commands to refresh the port.