Fabric OS Message Reference

53-1002749-01

CDR-1010

5

CDR-1010

Message

S<slot number>,C<chip index>: Internal monitoring of faults has identified suspect
hardware, blade may need to be reset or replaced: fault1:0x<fault1_cnt>,
fault2:0x<fault2_cnt> thresh2:0x<threshold_used>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that above-normal errors observed in hardware that may or may not impact the data traffic.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

CDR-1011

Message

S<slot number>,P<port number>(<blade port number>): Link Timeout on internal port
ftx=<frame transmitted> tov=<real timeout value> (><expected timeout value>)
vc_no=<vc number> crd(s)lost=<Credit(s) lost> complete_loss:<complete credit
loss>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or more credits have been lost on a back-end port, and there is no traffic on that port
for two seconds.

Recommended

Action

Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery has
already been turned on, the link will be reset to recover the credits and no action is required.

CDR-1012

Message

S<slot number>,P<port number>(<blade port number>): Port Fault: Hard <Hard
fault>(<Fault reason>) fault1=<Fault1 count> fault2=<Fault2 count> (0x<LIP and
LLI fault count> 0x<RX_FIFO and HSS fault count> 0x<BWAIT fault count>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port has failed. Port initialization will be retried.

Recommended

Action

Replace the SFP transceiver and the cable and then re-enable the port.