Rcs-1010, Rcs-1011, Rcs-1012 – Dell POWEREDGE M1000E User Manual

Page 697

Advertising
background image

Fabric OS Message Reference

675

53-1002749-01

RCS-1010

5

RCS-1010

Message

Domain <domain number> is RCS-incapable. Disabled <Number of E_ports disabled>
E_Port(s) connected to this domain.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified remote domain is RCS-incapable, or the RCS-capable information could not
be retrieved for the specified remote domain due to some potential routing issues.

Recommended

Action

Run the rcsInfoShow command to view RCS capability of the switch.

Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another
exchange of RCS-capable information.

RCS-1011

Message

Remote domain <domain number> is RCS-incapable. Configure this domain as
RCS-capable.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified remote domain is RCS-incapable, or the RCS-capable information could not
be retrieved for the specified remote domain due to some potential routing issues.

Recommended

Action

Run the rcsInfoShow command to view RCS capability of the switch.

Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another
exchange of RCS-capable information.

RCS-1012

Message

Local domain is RCS incapable (ForceDisabled is <Flag which denotes whether switch
is RCS capable or not>), hence reject the RCS_INFO request from domain <domain
number>.

Message Type

LOG | FFDC

Severity

WARNING

Probable Cause

Indicates that the specified domain is RCS-incapable.

Recommended

Action

Execute the supportSave command and contact your switch service provider.