Fabric OS Message Reference

53-1002749-01

AN-1010

5

AN-1010

Message

Severe latency bottleneck detected at slot <slot number> port <port number within
slot number>.

Message Type

LOG | AUDIT

Class

FABRIC

Severity

WARNING

Probable Cause

Indicates credit loss at the specified port, a downstream port, or a very high latency device at the edge of
the fabric.

Recommended

Action

Contact your switch service provider for assistance.

AN-1011

Message

Could not distinguish between primary and dependent severe latency bottleneck on
slot <slot number> port <port number within slot number> because port mirroring is
enabled on this port.

Message Type

LOG | AUDIT

Class

FABRIC

Severity

WARNING

Probable Cause

Indicates that resources that are needed to determine whether there is complete credit loss on a virtual
channel (VC) at the specified port are used by port mirroring.

Recommended

Action

Contact your switch service provider for assistance.

AN-1012

Message

Credits did not return from other end. Complete loss of credits on a VC on slot
<slot number> port <port number within slot number>.

Message Type

LOG | AUDIT

Class

FABRIC

Severity

WARNING

Probable Cause

Indicates a credit loss.

Recommended

Action

If this message is not followed by the AN-1013 message, contact your switch service provider for
assistance.