background image

Fabric OS Message Reference

199

53-1002749-01

C3-1018

5

C3-1018

Message

Link reset threshold value exceeded in the link S<slot number>,P<port
number>(<blade port number>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified blade is faulted because the link reset threshold value has exceeded.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

C3-1019

Message

S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an internal error is observed in the application-specific integrated circuit (ASIC) hardware
that may degrade the data traffic.

Recommended

Action

Restart the system at the next maintenance window.

C3-1020

Message

S<slot number>,P<port number>(<blade port number>): Some non-critical CRC with
good EOF errors were observed: current:0x<last_crc_good_eof_cnt>,
last:0x<total_crc_good_eof_cnt> thresh1:0x<threshold_used>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that some non-critical errors were detected in the hardware.

Recommended

Action

No action is required.