Fabric OS Message Reference

141

53-1002749-01

ANV-1004

5

ANV-1004

Message

S<slot number>,C<chip index>: Invalid DMA ch pointer, chan:<Channel number>,
good_addr:0x<Good address> bad_addr:0x<Bad address>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.

ANV-1005

Message

S<slot number>,C<chip index>,A<anvil id>: Memory allocation failed.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates memory allocation failure in the software.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.

ANV-1006

Message

S<slot number>,C<chip index>: HW ASIC Chip fault. Type = 0x<chip error type>,
Error = <chip error string>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders the
chip as not operational.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.