Fcr-1013, Fcr-1015, Fcr-1016 – Dell POWEREDGE M1000E User Manual
Page 371
Fabric OS Message Reference
349
53-1002749-01
FCR-1013
5
FCR-1013
Message
Phantom FSPF database exchange completed on port <port number>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified EX_Port has completed the fabric shortest path first (FSFP) database
exchange.
Recommended
Action
No action is required.
FCR-1015
Message
New EX_Port or VEX_Port added on port <port number> in domain <domain ID>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that an EX_Port was created on the specified port in the specified domain.
Recommended
Action
No action is required.
FCR-1016
Message
FCR fabric no longer reachable at port id <port number> (0x<port number (hex)>)
fabric ID <fabric ID>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link
or switch failure.
Recommended
Action
No action is required.