Cvlm messages, Cvlm-1001, Cvlm-1002 – Dell POWEREDGE M1000E User Manual
Page 280: Cvlm-1003
258
Fabric OS Message Reference
53-1002749-01
CVLM-1001
5
CVLM Messages
CVLM-1001
Message
Failed to allocate memory: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the memShow command.
Restart or power cycle the switch.
CVLM-1002
Message
Failed to initialize <module> rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of a module within the Crypto Virtual LUN Manager (CVLM) daemon has
failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command.
CVLM-1003
Message
Crypto device configuration has been committed by switch (<Switch WWN>).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified switch has committed a crypto device configuration.
Recommended
Action
No action is required.