Fabric OS Message Reference

295

53-1002749-01

EM-1070

5

EM-1070

Message

Slot <FRU slot number> is being powered on.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the blade in the specified slot is being intentionally powered on.

Recommended

Action

No action is required.

EM-1071

Message

Unit in <Slot number> with ID <FRU Id> is faulted, it is incompatible with the
following blade id(s): <blade incompatibility list>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that a blade inserted in the specified slot is incompatible with another blade in the system.

Recommended

Action

Determine which blade is essential to your configuration and remove blades that are incompatible with it.

EM-1072

Message

Chassis cannot become ready since no Core Blades are available.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that all core blades are either missing, faulted, or powered off. There must be at least one core
blade in enabled state for the chassis to be considered ready.

Recommended

Action

Insert and close the ejector switch on missing core blades. Reseat or replace core blades that are faulted
or powered off.