Fw-1126, Fw-1127 – Dell POWEREDGE M1000E User Manual

Page 476

Advertising
background image

454

Fabric OS Message Reference

53-1002749-01

FW-1126

5

Incompatible link parameters. During E_Port initialization, ports exchange link parameters.
Rarely, incompatible parameters result in segmentation.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1126

Message

<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of segmentations has fallen below the low boundary. Segmentation changes
might occur due to the following reasons:

Zone conflicts.

Domain conflicts.

Segmentation of the principal link between two switches.

Incompatible link parameters. During E_Port initialization, ports exchange link parameters.
Rarely, incompatible parameters result in segmentation.

A low number of segmentation errors means that the fabric is functioning normally.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1127

Message

<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of segmentations has risen above the high boundary. Segmentation changes
might occur due to the following reasons:

Zone conflicts.

Domain conflicts.

Segmentation of the principal link between two switches.

Incompatible link parameters. During E_Port initialization, ports exchange link parameters.
Rarely, incompatible parameters result in segmentation.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

Advertising