Fw-1167, Fw-1168, Fw-1169 – Dell POWEREDGE M1000E User Manual

Page 484

Advertising
background image

462

Fabric OS Message Reference

53-1002749-01

FW-1167

5

FW-1167

Message

<Port Name> <Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of synchronization losses that the port experiences has changed from a value
outside of the acceptable range to a value within the acceptable range. Loss of synchronization errors
frequently occur due to a faulty small form-factor pluggable (SFP) or cable. Signal losses often create
synchronization losses.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1168

Message

<Port Name> <Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of signal losses that the port experiences has changed. Loss of signal
generally indicates a physical problem.

Recommended

Action

Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs)
are not faulty.

FW-1169

Message

<Port Name> <Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of signal losses that the port experiences has fallen below the low boundary.
Loss of signal generally indicates a physical problem. A low number of signal loss errors means that the
switch is functioning normally.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.