C2-1019, C2-1025, C2-1026 – Dell POWEREDGE M1000E User Manual

Page 214

Advertising
background image

192

Fabric OS Message Reference

53-1002749-01

C2-1019

5

C2-1019

Message

S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an internal error is observed in the application-specific integrated circuit (ASIC) hardware
that may degrade the data traffic.

Recommended

Action

Restart the system at the next maintenance window.

C2-1025

Message

S<slot number>,P<port number>(<blade port number>): Extra credit on
F_port:ftx=<ftx> curr_cred=<current credits> actual_cred=<actual credits>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.

Recommended

Action

When this error is observed persistently, replace the device.

C2-1026

Message

S<slot number>,P<port number>(<blade port number>): Faulting F_port due to extra
credit detected:ftx=<ftx> curr_cred=<current credits> actual_cred=<actual
credits>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.

Recommended

Action

When this error is observed persistently, replace the device.

Advertising