Fabric OS Message Reference

247

53-1002749-01

CVLC-1007

5

CVLC-1007

Message

Removal of encryption LUN is not allowed when decrypt of existing data is enabled.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that there has been an attempt to remove the encryption LUN while decryption of existing data
is still enabled.

Recommended

Action

To preserve the user data, execute the cryptocfg --modify -LUN -cleartext command to convert to
cleartext LUN.

Use the cryptocfg --modify -LUN -cleartext command to disable decryption of existing data.

Then try to delete the LUN again.

CVLC-1008

Message

LUN discovery failure: <Discovery state>, Container: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that LUN discovery failed.

Recommended

Action

No action is required.

CVLC-1009

Message

Wrong device type: should be <Expected device type (Disk/Tape)>, found <Discovered
device type (Disk/Tape)>. Container: <Target container name>, Initiator:
<Initiator physical WWN>, LUN ID: <LUN ID>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that LUN discovery failed.

Recommended

Action

No action is required.