Mcast_ss-1004, Mcast_ss-1005, Mcast_ss-1006 – Dell POWEREDGE M1000E User Manual
Page 627

Fabric OS Message Reference
605
53-1002749-01
MCAST_SS-1004
5
MCAST_SS-1004
Message
NSM error: <op> (<reason>) for VLAN <vid> port <port>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the multicast subsystem (MCAST_SS) has encountered an error during a network service
module (NSM) event.
Recommended
Action
Restart the MCAST_SS daemon.
MCAST_SS-1005
Message
Message error: Invalid message type <type> expecting <value1> or <value2> or
<value3>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the type of the message received from the driver is invalid.
Recommended
Action
Restart the MCAST_SS daemon.
MCAST_SS-1006
Message
Message error: <op> (<reason>) Invalid message length <length> expecting
<length1>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that length of the message received from the driver is invalid.
Recommended
Action
Restart the MCAST_SS daemon.