Zeus messages, Zeus-1001, Zeus-1002 – Dell POWEREDGE M1000E User Manual

Page 911: Zeus-1003

Advertising
background image

Fabric OS Message Reference

889

53-1002749-01

ZEUS-1001

5

ZEUS Messages

ZEUS-1001

Message

Port <port number> port fault. Change the SFP or check cable.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.

Recommended

Action

Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.

ZEUS-1002

Message

Port <port number> chip faulted due to internal error.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates an internal error. All ports on the blade or switch will be disrupted.

Recommended

Action

To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.

ZEUS-1003

Message

S<slot number>,C<chip index>: HW ASIC Chip error type = 0x<chip error type>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

Reboot the system at the next maintenance window. If the problem persists, replace the blade.