246

Fabric OS Message Reference

53-1002749-01

CVLC-1004

5

CVLC-1004

Message

Forceful encryption LUN removal while re-key session is still active. Container:
<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the encryption LUN was forcefully removed while a re-key session was still active.

Recommended

Action

No action is required.

CVLC-1005

Message

There are no LUNs found from the target. Container: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that there are no LUNs found from the target-initiator pair.

Recommended

Action

No action is required.

CVLC-1006

Message

Duplicate LUN serial number <LUN SN> found. Container: <Target container name>,
Initiator: <Initiator physical WWN>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there is more than one LUN serial number discovered from the same target. Therefore,
encryption on this target is disabled.

Recommended

Action

No action is required.