CVLC-1025

5

CVLC-1025

Message

Secondary Metadata exists for encrypted LUN not configured with -newLUN option.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the secondary metadata exists on the LUN that is not configured with the -newLUN option.

Recommended

Action

Use the cryptoCfg command to remove and add the LUN with the -newLUN option.

CVLC-1026

Message

Some secondary metadata missing for encrypted LUN configured with -newLUN option.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the secondary metadata does not exist on all logical block addresses (LBAs) for a LUN that
is configured with the -newLUN option.

Recommended

Action

No action is required.

CVLC-1027

Message

Encrypted LUN configured with -newLUN option does not contain any metadata.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the metadata was corrupted.

Recommended

Action

No action is required.