Fabric OS Message Reference

813

53-1002749-01

SSMD-1201

5

SSMD-1201

Message

QoS failed programming ASIC <ASIC slot number>/<ASIC chip number> Multicast Tail
Drop.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the Multicast Tail Drop feature.

Recommended

Action

Delete and reapply the QoS Multicast Tail Drop policy using the qos rcv-queue multicast threshold
command.

If the problem persists, restart or power cycle the switch.

SSMD-1202

Message

QoS failed programming interface 0x<Interface ID> 802.3x Pause flow control.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing interface 802.3x Pause flow control feature.

Recommended

Action

Delete and reapply the QoS 802.3x Pause flow control policy using the qos flowcontrol command.

If the problem persists, restart or power cycle the switch.

SSMD-1203

Message

QoS failed programming interface 0x<Interface ID> PFC flow control.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing interface Priority-based Flow Control (PFC) flow control feature.

Recommended

Action

Delete and reapply the QoS PFC flow control policy using the qos flowcontrol pfc command.

If the problem persists, restart or power cycle the switch.