Cdr-1014, Cdr-1015, Cdr-1016 – Dell POWEREDGE M1000E User Manual

Page 233

Advertising
background image

Fabric OS Message Reference

211

53-1002749-01

CDR-1014

5

CDR-1014

Message

Link Reset on Internal Port S<slot number>,P<port number>(<blade port number>)
vc_no=<vc number> crd(s)lost=<Credit(s) lost>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or more credits were lost and the link is reset.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

CDR-1015

Message

Port re-initialized due to Link Reset failure on internal Port S<slot
number>,P<port number>(<blade port number>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that specified port got re-initialized due to link reset failure.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

CDR-1016

Message

Port is faulted due to port re-initialization failure on internal Port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified port is faulted due to port re-initialization failure.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

Advertising