Fspf-1008, Fspf-1009, Fspf-1010 – Dell POWEREDGE M1000E User Manual

Page 452: Fspf-1011

Advertising
background image

430

Fabric OS Message Reference

53-1002749-01

FSPF-1008

5

FSPF-1008

Message

ICL triangular topology is formed among the domains: <domain number> (self),
<domain number>, and <domain number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the inter-chassis link (ICL) triangular topology is formed.

Recommended

Action

No action is required.

FSPF-1009

Message

16G ICL topology is not recommended on local domain <domain number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the current 16 Gbps inter-chassis link (ICL) topology is not recommended.

Recommended

Action

Use the switchShow, islShow, and lsdbShow commands to identify the neighbor domains that violate
the ICL connectivity requirement.

FSPF-1010

Message

ICL Topology is valid on local domain <domain number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the current inter-chassis link (ICL) topology is valid for routing from the local switch.

Recommended

Action

No action is required.

FSPF-1011

Message

16G ICL topology is unbalanced.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the current configuration of inter-chassis link (ICL) paths are unbalanced.

Advertising