Fw-1200, Fw-1201, Fw-1202 – Dell POWEREDGE M1000E User Manual

Page 495

Advertising
background image

Fabric OS Message Reference

473

53-1002749-01

FW-1200

5

FW-1200

Message

<Port Name> <Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of C3 transmit timeout frames has changed.

Recommended

Action

Check the target device; it could be slow.

FW-1201

Message

<Port Name> <Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of C3 transmit timeout frames is below the low threshold. A low number of C3
transmit timeout means that the switch is functioning normally.

Recommended

Action

Respond to this message as is appropriate to the particular policy of the end-user installation.

FW-1202

Message

<Port Name> <Label>, is above high boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

AUDIT | LOG

Class

FW

Severity

ERROR

Probable Cause

Indicates that the number of C3 transmit timeout frames is above the high threshold.

Recommended

Action

Check the target device; it could be slow.