Sec-1119, Sec-1121, Sec-1122 – Dell POWEREDGE M1000E User Manual

Page 741

Advertising
background image

Fabric OS Message Reference

719

53-1002749-01

SEC-1119

5

SEC-1119

Message

Secure mode has been enabled.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the secure Fabric OS was enabled by the secModeEnable command.

Recommended

Action

Verify the security event was planned. If the security event was planned, there is no action required. If the
security event was not planned, take appropriate action as defined by your enterprise security policy.

SEC-1121

Message

Time is out of range when <text>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the time on the switch is not synchronized with the primary fabric configuration server (FCS),
the data packet is corrupted, or a replay attack is launched on the switch.

Recommended

Action

Verify the security event was planned. If the security event was planned, verify that all switches in the
fabric are in time synchronization with the primary FCS and that no external entity is trying to access the
fabric. When verification is complete, retry the operation.

SEC-1122

Message

Error code: <Domain ID>, <Error message>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that one of the switches in the fabric could not communicate with the primary fabric
configuration server (FCS).

Recommended

Action

Run the fabricShow command to verify that all switches in the fabric are in the ready state. When all
switches are in the ready state, retry the operation.

Advertising