Fw-1054, Fw-1113, Fw-1114 – Dell POWEREDGE M1000E User Manual

Page 471

Advertising
background image

Fabric OS Message Reference

449

53-1002749-01

FW-1054

5

FW-1054

Message

<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) Power on Hours has risen above the
high boundary. The high value indicates the maximum lifetime use of the SFP.

Recommended

Action

Replace the SFP.

FW-1113

Message

<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of times E_Ports have gone down has changed. E_Ports go down each time
you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go down.
Down E_Port may be caused by transient errors.

Recommended

Action

Check both ends of the physical connection and verify that the SFPs and cables are functioning properly.

FW-1114

Message

<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of times E_Ports have gone down has fallen below the low boundary. E_Ports
go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause
E_Ports to go down. Down E_Port may be caused by transient errors.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. A low number of E_Port failures means that the switch is functioning normally.