806

Fabric OS Message Reference

53-1002749-01

SS-1003

5

SS-1003

Message

supportSave's operation to USB storage device aborted.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a USB operation error occurred during execution of the supportSave command. Complete
error information cannot always be displayed in this message because of possible errors in
subcommands being executed by the supportSave command.

Recommended

Action

Execute the usbstorage command to check the USB storage device settings. After the USB problem is
corrected, execute the supportSave command again.

SS-1004

Message

One or more modules timed out during supportsave. Retry supportsave with -t option
to collect all logs.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a timeout in modules during the execution of the supportSave command.

Recommended

Action

Execute the supportSave -t [2-5] command to collect all logs.

SS-1005

Message

supportsave failed for the slot <Slot Number>. Reason: No IP connection.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there is no IP connection between the active control processor (CP) and the blade in the
specified slot.

Recommended

Action

Check for the IP connection between the active CP and the blade in the specified slot. After the IP
connection is established, execute the supportSave command again.