Ccfg messages, Ccfg-1001, Ccfg-1002 – Dell POWEREDGE M1000E User Manual
Page 225: Ccfg-1003

Fabric OS Message Reference
203
53-1002749-01
CCFG-1001
5
CCFG Messages
CCFG-1001
Message
Failed to initialize <module>, rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of a module within the Converged Enhanced Ethernet (CEE) configuration
management daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command.
CCFG-1002
Message
Started loading CEE system configuration.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the Converged Enhanced Ethernet (CEE) system configuration has started loading.
Recommended
Action
No action is required.
CCFG-1003
Message
System is ready to accept CEE user commands.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the Converged Enhanced Ethernet (CEE) shell is ready to accept configuration
commands.
Recommended
Action
No action is required.