Ns-1010, Ns-1011, Ns-1012 – Dell POWEREDGE M1000E User Manual

Page 654

Advertising
background image

632

Fabric OS Message Reference

53-1002749-01

NS-1010

5

NS-1010

Message

CSCTL mode enabled on port <csctlport> QoS zoning will be ignored for devices on
this port.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that class-specific control (CS_CTL) mode has been enabled on the specified port that has
devices as members of a quality of service (QoS) zone.

Recommended

Action

Remove the CS_CTL configured devices from the QoS zone.

NS-1011

Message

NS has detected a failover flag disabled TI zone in a base switch <Domain Id> in
fabric ID <Fabric ID>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a failover-disabled traffic isolation (TI) zone has been detected in a base switch fabric.

Recommended

Action

Enable the failover flag or remove the TI zone with the disabled failover flag because the routing may not
be set up correctly.

NS-1012

Message

Detected duplicate WWPN [<WWPN>] - devices removed with PID 0x<existing device
PID> and 0x<new device PID>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the devices with the same World Wide Port Name (WWPN) have been removed from the
Name Server database.

Recommended

Action

Verify the device reported with duplicate WWPN.

Advertising