background image

Fabric OS Message Reference

645

53-1002749-01

PDM-1010

5

PDM-1010

Message

File open failed: <file name>, errno=<errno>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the Parity Data Manager (PDM) process could not open the specified file.

Recommended

Action

Execute the firmwareDownload command to reinstall the firmware.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

PDM-1011

Message

File read failed: <file name>, Length(read=<Number of character read>,
expected=<Number of characters expected>), errno=<errno returned by read>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the Parity Data Manager (PDM) process could not read data from the specified file.

Recommended

Action

Execute the firmwareDownload command to reinstall the firmware.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

PDM-1012

Message

File write failed: <file name>. Length(read=<Number of character read>,
write=<Number of characters written>), errno=<errno returned by write>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the Parity Data Manager (PDM) process could not write data to the specified file.

Recommended

Action

Execute the firmwareDownload command to reinstall the firmware.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.