Fabric OS Message Reference

175

53-1002749-01

BL-1034

5

BL-1034

Message

Slot <slot number> FC Initialization completed.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the slot has completed initializing the Fibre Channel (FC) ports.

Recommended

Action

No action is required.

BL-1035

Message

Slot <slot number> iSCSI port <iscsi port number> Initialization completed.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the slot has completed initializing the specified iSCSI port.

Recommended

Action

No action is required.

BL-1036

Message

Faulting 8G blade in slot = <slot number> due to incompatible stag mode. All
EX/VEX ports must be disabled in order to enable the 8G blade in the chassis.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the 8 Gbps blade with legacy mode (EX_port having stag) will be disabled.

Recommended

Action

Disable all EX_Ports and VEX_Ports and execute the slotPowerOff or slotPowerOn commands on the
8 Gbps blade. All EX_Ports and VEX_Ports can be re-enabled.