Fabric OS Message Reference

291

53-1002749-01

EM-1058

5

EM-1058

Message

Switch gets reset:<Fault reason>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the switch is being automatically reset because of a known resetable transient problem
such as an application-specific integrated circuit (ASIC) parity error.

Recommended

Action

No action is required if the switch does not reach the reset threshold for the switch or blade. If the reset
threshold is reached on the switch or blade, the switch or blade will be faulted and should be replaced.

EM-1059

Message

<Slot number or Switch> with ID <Blade Id> may not be supported on this platform,
check FOS firmware version as a possible cause.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a a blade inserted in the specified slot or the switch (for non-bladed switches) is
incompatible with the switch configuration software. The blade will not be completely usable.

The blade may only be supported by a later (or earlier) version of the firmware.

Recommended

Action

Change the control processor (CP) firmware or replace the blade. Make sure the replacement is
compatible with your switch type and firmware.

EM-1060

Message

Stopping synchronization of the system due to blade incompatibility with software
version on standby CP.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a blade in the system is not supported by the firmware on the standby control processor
(CP).

Recommended

Action

Remove all blades of this type or upgrade the standby CP. After an appropriate action is taken, restart the
standby CP or execute the haSyncStart command to enable the high availability (HA) state
synchronization. Until this is done, the system will remain out of synchronization.