Cdr-1017, Cdr-1018, Cdr-1019 – Dell POWEREDGE M1000E User Manual

Page 234

Advertising
background image

212

Fabric OS Message Reference

53-1002749-01

CDR-1017

5

CDR-1017

Message

Blade in Slot <slot number> faulted due to unavailable ports in internal Trunk.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified blade is faulted due to unavailable ports in internal trunk.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

CDR-1018

Message

Blade in Slot <slot number> faulted due to Link reset threshold value exceeded.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified blade is faulted because the link reset threshold is exceeded.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

CDR-1019

Message

S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an internal error is observed in the application-specific integrated circuit (ASIC) hardware
that may degrade the data traffic.

Recommended

Action

Restart the system at the next maintenance window.

Advertising