196

Fabric OS Message Reference

53-1002749-01

C3-1009

5

C3-1009

Message

S<slot number>,P<port number>(<blade port number>): portcfglongdistance
vc_translation_link_init = 1 overwrites fill word IDLE. ARB will be used on the
link.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the portcfglongdistance vc_translation_link_init 1 command has overwritten the fill
word IDLE. Arbitrated loop (ARB) will be used on the link.

Recommended

Action

No action is required.

C3-1010

Message

S<slot number>,C<chip index>: Above normal hardware errors were observed:
fault1:0x<fault1_cnt>, fault2:0x<fault2_cnt> thresh2:0x<threshold_used>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that above-normal errors were observed in hardware that may or may not impact the data
traffic.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

C3-1011

Message

Detected a complete loss of credit on internal back-end VC: Slot <slot number>,
Port <port number>(<blade port number>) vc_no=<vc number> crd(s)lost=<Credit(s)
lost>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that all credits have been lost on the specified virtual channel (VC) and port.

Recommended

Action

Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery has
already been turned on, the link will be reset to recover the credits and no action is required.