Fcph-1004, Fcph-1005 – Dell POWEREDGE M1000E User Manual

Page 366

Advertising
background image

344

Fabric OS Message Reference

53-1002749-01

FCPH-1004

5

FCPH-1004

Message

NPIV port <Port Number> has same Port WWN as old port <Port Number> with pid
0x<Port PID> as part of duplicate Port WWN detection policy.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified N_Port ID virtualization (NPIV) port has the same Port World Wide Name
(PWWN) as the old port.

Recommended

Action

No action is required.

FCPH-1005

Message

FDISC exch=0x<ExchangeId> sid=0x<SourceID> did=0x<DestinationID> on port <Port>
rejected; temporary mem alloc error. Please bounce port of affected device.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that in busy login conditions, the buffer used for quick memory allocations (known as atomic
malloc
) can be quickly depleted and not replenished before the next allocation occurs.

Recommended

Action

Reset the specified port using the portDisable and portEnable commands.

Advertising