Fabric OS Message Reference

53-1002749-01

SPC-3011

5

SPC-3011

Message

S<slot number containing Encryption Engine>, <module name>: Persistent data
storage error: <SP status code>, KEK: <KEK octet 1> <KEK octet 2> <KEK octet 3>
<KEK octet 4>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an attempt to store CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.

Recommended

Action

Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
needed primary and secondary KEKs.

SPC-3012

Message

S<slot number containing Encryption Engine>, <module name>: Persistent data
retrieval error: <SP status code>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an attempt to read CryptoModule internal data using the Secret Encryption Key failed;
most likely, the encryption engine has been zeroized or tampered with.

Recommended

Action

Execute the cryptocfg --initEE and cryptocfg --regEE commands, and then recover or restore the
needed primary and secondary KEKs.

SPC-3013

Message

S<slot number containing Encryption Engine>, <module name>: SEK generation
failure: <SP status code>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the CryptoModule internal Secret Encryption Key could not be generated.

Recommended

Action

Contact your switch service provider for assistance.