140

Fabric OS Message Reference

53-1002749-01

ANV-1001

5

ANV Messages

ANV-1001

Message

Port <port number> port fault. Change the SFP or check the cable.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.

Recommended

Action

Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable, if
necessary.

ANV-1002

Message

Port <port number> chip faulted due to an internal error.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates an internal error. All the ports on the chip will be disrupted.

Recommended

Action

To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.

ANV-1003

Message

S<slot number>,C<chip index>: HW ASIC Chip error. Type = 0x<chip error type>,
Error = <chip error string>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.