Ssmd messages, Ssmd-1001, Ssmd-1002 – Dell POWEREDGE M1000E User Manual
Page 832: Ssmd-1003
810
Fabric OS Message Reference
53-1002749-01
SSMD-1001
5
SSMD Messages
SSMD-1001
Message
Failed to allocate memory: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the memShow command.
Restart or power cycle the switch.
SSMD-1002
Message
Failed to initialize <module> rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of a module within System Services Manager (SSM) has failed.
Recommended
Action
Download a new firmware using the firmwareDownload command.
SSMD-1003
Message
Failed to lock semaphore mutex: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to lock the mutex (semaphore).
Recommended
Action
Restart or power cycle the switch.