background image

Fabric OS Message Reference

373

53-1002749-01

FCR-1097

5

FCR-1097

Message

Failed to get <data type> for <message phase> message: port <port number>, retval
<error code>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the authentication process failed to get a particular authentication value at certain phase.

Data type is the payload or structure that failed to get memory.

Recommended

Action

Usually this problem is transient. The authentication may fail.

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.

FCR-1098

Message

Invalid message code for <message phase> message: port <port number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the receiving payload does not have valid message code for a particular authentication phase.

Recommended

Action

Usually this problem is transient. The authentication may fail.

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.

Advertising